【SL1168 型錄下載】
SL1168 Wall Mount (Economical Type) Electronics with clamp-on transducers
Model
|
Description
|
SL1168①
|
Digital Correlation Transit Time Flowmeter Installation method: wall mount Transmitter: Flow Range: ±0 to 16ft/s (±0 to 5 m/s) Accuracy: ±1% of measurement; Repeatability: 0.3% Pipe Size Range:25mm ~ 800mm Keyboard:16(4×4)touch keys Display: 20*2, alphanumeric, backlit LCD Power supply: 10-30V DC@1Amax Transmitter enclosure: IP65, ABS/PC enclosure Temperature:-20~50℃ Output: OCT pulse output 0-10KHz, Relay output. 4-20mA optional Communication: RS232, Modbus Protocol Transducer: Pipe size: 25~800mm Clamp on type, PC package Temperature. 0~60℃ Cable length: 9m Protection rating:IP68
|
Code1
|
Option
|
4
|
OCT output, Relay output, RS232,RTD Temperature input
|
Code2
|
Type of transducers
|
CP WS
|
Clamp on transducer, Operating temperature: 0 ~ +60℃ Insertion transducer (small), Operating temperature: -40 ~ +80℃, apply to the pipe size below DN400
|
Normal Model: SL1168-4-CP Description: standard enclosure with Clamp-on transducers, OCT pulse out, Relay output, RS232, 9m cable. 4-20mA output
|
|